spectral10ToDensity

public final DoubleArray spectral10ToDensity(IntArray lambda, FloatArray reflectance, DensityStatus status)

Takes reflectance data on 10 nm intervals and calculates CMYK densities according to ISO 5-3:2009. Data must be provided on 10 nm intervals corresponding to the nearest 10 nanometer. Density values are calculated across the range 340 - 770 nm. If the provided data spans a shorter range (eg - 400 - 700 nm), the values at the boundaries are repeated.

Return

CMYK densities (element order C, M, Y, K)

Since

4.0.2

Parameters

lambda

Wavelength values of provided reflectance data.

reflectance

Reflectance data. Must contain the same number of elements as lambda

status

Selected density status